Nexans HEPR-PVC 0,6/1kV
Nexans HEPR-PVC 0,6/1kV
Nexans HEPR-PVC 0.6/1kV cable (formerly Fiter Flex) allows you to raise the standard of your electrical installations. The flexible copper conductor, class 5, is a superior choice for those looking for efficiency and safety. Insulated in high quality HEPR and protected by an ST2 type PVC cover. This cable is designed to withstand the most demanding conditions. With a thermal tolerance of up to 90°C and a capacity of 0.6/1 kV, it is perfectly suited to a wide range of industrial and construction applications. It is available in sections from 1.5 mm² to 630 mm², depending on the number of conductors (from 1 to 5). See technical details below:
Read moreNexans HEPR-PVC 0.6/1kV 1x1.5mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.5 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 0.9 mm
- Outer Diameter: 5 mm
- Approximate weight: 34.14 kg/km
Nexans HEPR-PVC 0.6/1kV 1x2.5mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.97 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 0.9 mm
- Outer Diameter: 5.5 mm
- Approximate weight: 46.81 kg/km
Nexans HEPR-PVC 0.6/1kV 1x4mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.45 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 0.9 mm
- Outer Diameter: 6 mm
- Approximate weight: 62.55 kg/km
Nexans HEPR-PVC 0.6/1kV 1x6mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.0 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 0.9 mm
- Outer Diameter: 6.5 mm
- Approximate weight: 81.97 kg/km
Nexans HEPR-PVC 0.6/1kV 1x10mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 10 mm²
- Conductor diameter: 3.9 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1 mm
- Outer Diameter: 7.5 mm
- Approximate weight: 126.2 kg/km
Nexans HEPR-PVC 0.6/1kV 1x16mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 16 mm²
- Conductor diameter: 4.93 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1 mm
- Outer Diameter: 8.5 mm
- Approximate weight: 181 kg/km
Nexans HEPR-PVC 0.6/1kV 1x25mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 25 mm²
- Conductor diameter: 6.16 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.1 mm
- Outer Diameter: 10.5 mm
- Approximate weight: 275.2 kg/km
Nexans HEPR-PVC 0.6/1kV 1x35mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 35 mm²
- Conductor diameter: 7.33 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.1 mm
- Outer Diameter: 12 mm
- Approximate weight: 369.4 kg/km
Nexans HEPR-PVC 0.6/1kV 1x50mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 50 mm²
- Conductor diameter: 9.0 mm
- Nominal insulation thickness: 1.0 mm
- Protective Covering Nominal Thickness: 1.2 mm
- Outer Diameter: 14 mm
- Approximate weight: 517.2 kg/km
Nexans HEPR-PVC 0.6/1kV 1x70mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 70 mm²
- Conductor diameter: 10.75 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.2 mm
- Outer Diameter: 16 mm
- Approximate weight: 712.3 kg/km
Nexans HEPR-PVC 0.6/1kV 1x95mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 95 mm²
- Conductor diameter: 12.2 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.3 mm
- Outer Diameter: 17.5 mm
- Approximate weight: 942.3 kg/km
Nexans HEPR-PVC 0.6/1kV 1x120mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 120 mm²
- Conductor diameter: 13.82 mm
- Nominal insulation thickness: 1.2 mm
- Protective Covering Nominal Thickness: 1.3 mm
- Outer Diameter: 19.5 mm
- Approximate weight: 1881 kg/km
Nexans HEPR-PVC 0.6/1kV 1x150mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 150 mm²
- Conductor diameter: 15.24 mm
- Nominal insulation thickness: 1.4 mm
- Protective Covering Nominal Thickness: 1.4 mm
- Outer Diameter: 21.5 mm
- Approximate weight: 1462 kg/km
Nexans HEPR-PVC 0.6/1kV 1x185mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 185 mm²
- Conductor diameter: 16.98 mm
- Nominal insulation thickness: 1.6 mm
- Protective Covering Nominal Thickness: 1.4 mm
- Outer Diameter: 24 mm
- Approximate weight: 1765 kg/km
Nexans HEPR-PVC 0.6/1kV 1x240mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 240 mm²
- Conductor diameter: 19.76 mm
- Nominal insulation thickness: 1.7 mm
- Protective Covering Nominal Thickness: 1.5 mm
- Outer Diameter: 27 mm
- Approximate weight: 2314 kg/km
Nexans HEPR-PVC 0.6/1kV 1x300mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 300 mm²
- Conductor diameter: 22.62 mm
- Nominal insulation thickness: 1.8 mm
- Protective Covering Nominal Thickness: 1.6 mm
- Outer Diameter: 31 mm
- Approximate weight: 2839 kg/km
Nexans HEPR-PVC 0.6/1kV 1x400mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 400 mm²
- Conductor diameter: 26.5 mm
- Nominal insulation thickness: 2.0 mm
- Protective Covering Nominal Thickness: 1.7 mm
- Outer Diameter: 35.5 mm
- Approximate weight: 3785 kg/km
Nexans HEPR-PVC 0.6/1kV 1x500mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 500 mm²
- Conductor diameter: 28.6 mm
- Nominal insulation thickness: 2.2 mm
- Protective Covering Nominal Thickness: 1.8 mm
- Outer Diameter: 38 mm
- Approximate weight: 4760 kg/km
Nexans HEPR-PVC 0.6/1kV 1x630mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 630 mm²
- Conductor diameter: 34.7 mm
- Nominal insulation thickness: 2.4 mm
- Protective Covering Nominal Thickness: 2 mm
- Outer Diameter: 45 mm
- Approximate weight: 6369 kg/km
Nexans HEPR-PVC 0.6/1kV 2x1.5mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.5 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1 mm
- Outer Diameter: 8 mm
- Approximate weight: 91.21 kg/km
Nexans HEPR-PVC 0.6/1kV 2x2.5mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.97 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.1 mm
- Outer Diameter: 9 mm
- Approximate weight: 126.2 kg/km
Nexans HEPR-PVC 0.6/1kV 2x4mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.45 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.1 mm
- Outer Diameter: 10 mm
- Approximate weight: 167 kg/km
Nexans HEPR-PVC 0.6/1kV 2x6mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.0 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.1 mm
- Outer Diameter: 11.5 mm
- Approximate weight: 218.8 kg/km
Nexans HEPR-PVC 0.6/1kV 2x10mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 10 mm²
- Conductor diameter: 3.9 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.2 mm
- Outer Diameter: 13.5 mm
- Approximate weight: 329 kg/km
Nexans HEPR-PVC 0.6/1kV 2x16mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 16 mm²
- Conductor diameter: 4.93 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.2 mm
- Outer Diameter: 15.5 mm
- Approximate weight: 472.6 kg/km
Nexans HEPR-PVC 0.6/1kV 2x25mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 25 mm²
- Conductor diameter: 6.16 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.3 mm
- Outer Diameter: 19 mm
- Approximate weight: 722.9 kg/km
Nexans HEPR-PVC 0.6/1kV 2x35mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 35 mm²
- Conductor diameter: 7.33 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.4 mm
- Outer Diameter: 22 mm
- Approximate weight: 972.9 kg/km
Nexans HEPR-PVC 0.6/1kV 2x50mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 50 mm²
- Conductor diameter: 9.0 mm
- Nominal insulation thickness: 1.0 mm
- Protective Covering Nominal Thickness: 1.5 mm
- Outer Diameter: 26 mm
- Approximate weight: 1223 kg/km
Nexans HEPR-PVC 0.6/1kV 2x70mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 70 mm²
- Conductor diameter: 10.75 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.6 mm
- Outer Diameter: 30.5 mm
- Approximate weight: 1795 kg/km
Nexans HEPR-PVC 0.6/1kV 2x95mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 95 mm²
- Conductor diameter: 12.2 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.8 mm
- Outer Diameter: 34 mm
- Approximate weight: 2348 kg/km
Nexans HEPR-PVC 0.6/1kV 2x120mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 120 mm²
- Conductor diameter: 13.82 mm
- Nominal insulation thickness: 1.2 mm
- Protective Covering Nominal Thickness: 1.9 mm
- Outer Diameter: 38 mm
- Approximate weight: 2925 kg/km
Nexans HEPR-PVC 0.6/1kV 2x150mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 150 mm²
- Conductor diameter: 15.24 mm
- Nominal insulation thickness: 1.4 mm
- Protective Covering Nominal Thickness: 2 mm
- Outer Diameter: 42 mm
- Approximate weight: 3588 kg/km
Nexans HEPR-PVC 0.6/1kV 2x185mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 185 mm²
- Conductor diameter: 16.98 mm
- Nominal insulation thickness: 1.6 mm
- Protective Covering Nominal Thickness: 2.1 mm
- Outer Diameter: 46.5 mm
- Approximate weight: 4252 kg/km
Nexans HEPR-PVC 0.6/1kV 2x240mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 240 mm²
- Conductor diameter: 19.76 mm
- Nominal insulation thickness: 1.7 mm
- Protective Covering Nominal Thickness: 2.3 mm
- Outer Diameter: 51.5 mm
- Approximate weight: 5669 kg/km
Nexans HEPR-PVC 0.6/1kV 2x300mm2
Nexans ref.
- Number of cores: 2
- Conductor cross-section: 300 mm²
- Conductor diameter: 22.62 mm
- Nominal insulation thickness: 1.8 mm
- Protective Covering Nominal Thickness: 2.5 mm
- Outer Diameter: 58 mm
- Approximate weight: 6837 kg/km
Nexans HEPR-PVC 0.6/1kV 3x1.5mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.5 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1 mm
- Outer Diameter: 8.5 mm
- Approximate weight: 106.8 kg/km
Nexans HEPR-PVC 0.6/1kV 3x2.5mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.97 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.1 mm
- Outer Diameter: 10 mm
- Approximate weight: 150.1 kg/km
Nexans HEPR-PVC 0.6/1kV 3x4mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.45 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.1 mm
- Outer Diameter: 11 mm
- Approximate weight: 202.5 kg/km
Nexans HEPR-PVC 0.6/1kV 3x6mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.0 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.1 mm
- Outer Diameter: 12 mm
- Approximate weight: 269.9 kg/km
Nexans HEPR-PVC 0.6/1kV 3x10mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 10 mm²
- Conductor diameter: 3.9 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.2 mm
- Outer Diameter: 14 mm
- Approximate weight: 413 kg/km
Nexans HEPR-PVC 0.6/1kV 3x16mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 16 mm²
- Conductor diameter: 4.93 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.3 mm
- Outer Diameter: 17 mm
- Approximate weight: 611.2 kg/km
Nexans HEPR-PVC 0.6/1kV 3x25mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 25 mm²
- Conductor diameter: 6.16 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.4 mm
- Outer Diameter: 21 mm
- Approximate weight: 934.3 kg/km
Nexans HEPR-PVC 0.6/1kV 3x35mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 35 mm²
- Conductor diameter: 7.33 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.5 mm
- Outer Diameter: 23.5 mm
- Approximate weight: 1265 kg/km
Nexans HEPR-PVC 0.6/1kV 3x50mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 50 mm²
- Conductor diameter: 9.0 mm
- Nominal insulation thickness: 1.0 mm
- Protective Covering Nominal Thickness: 1.6 mm
- Outer Diameter: 28 mm
- Approximate weight: 1695 kg/km
Nexans HEPR-PVC 0.6/1kV 3x70mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 70 mm²
- Conductor diameter: 10.75 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.7 mm
- Outer Diameter: 33 mm
- Approximate weight: 2325 kg/km
Nexans HEPR-PVC 0.6/1kV 3x95mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 95 mm²
- Conductor diameter: 12.2 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.8 mm
- Outer Diameter: 36 mm
- Approximate weight: 3068 kg/km
Nexans HEPR-PVC 0.6/1kV 3x120mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 120 mm²
- Conductor diameter: 13.82 mm
- Nominal insulation thickness: 1.2 mm
- Protective Covering Nominal Thickness: 1.9 mm
- Outer Diameter: 40 mm
- Approximate weight: 3850 kg/km
Nexans HEPR-PVC 0.6/1kV 3x150mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 150 mm²
- Conductor diameter: 15.24 mm
- Nominal insulation thickness: 1.4 mm
- Protective Covering Nominal Thickness: 2.1 mm
- Outer Diameter: 45 mm
- Approximate weight: 4811 kg/km
Nexans HEPR-PVC 0.6/1kV 3x185mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 185 mm²
- Conductor diameter: 16.98 mm
- Nominal insulation thickness: 1.6 mm
- Protective Covering Nominal Thickness: 2.3 mm
- Outer Diameter: 50 mm
- Approximate weight: 5845 kg/km
Nexans HEPR-PVC 0.6/1kV 3x240mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 240 mm²
- Conductor diameter: 19.76 mm
- Nominal insulation thickness: 1.7 mm
- Protective Covering Nominal Thickness: 2.4 mm
- Outer Diameter: 57 mm
- Approximate weight: 7617 kg/km
Nexans HEPR-PVC 0.6/1kV 3x300mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 300 mm²
- Conductor diameter: 22.62 mm
- Nominal insulation thickness: 1.8 mm
- Protective Covering Nominal Thickness: 2.6 mm
- Outer Diameter: 62 mm
- Approximate weight: 9476 kg/km
Nexans HEPR-PVC 0.6/1kV 4x1.5mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.5 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.1 mm
- Outer Diameter: 9.5 mm
- Approximate weight: 132.8 kg/km
Nexans HEPR-PVC 0.6/1kV 4x2.5mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.97 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.1 mm
- Outer Diameter: 11 mm
- Approximate weight: 180.8 kg/km
Nexans HEPR-PVC 0.6/1kV 4x4mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.45 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.2 mm
- Outer Diameter: 12 mm
- Approximate weight: 268.9 kg/km
Nexans HEPR-PVC 0.6/1kV 4x6mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.0 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.2 mm
- Outer Diameter: 13.5 mm
- Approximate weight: 357.5 kg/km
Nexans HEPR-PVC 0.6/1kV 4x10mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 10 mm²
- Conductor diameter: 3.9 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.3 mm
- Outer Diameter: 16 mm
- Approximate weight: 521.9 kg/km
Nexans HEPR-PVC 0.6/1kV 4x16mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 16 mm²
- Conductor diameter: 4.93 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.3 mm
- Outer Diameter: 18.5 mm
- Approximate weight: 764 kg/km
Nexans HEPR-PVC 0.6/1kV 4x25mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 25 mm²
- Conductor diameter: 6.16 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.5 mm
- Outer Diameter: 23 mm
- Approximate weight: 1182 kg/km
Nexans HEPR-PVC 0.6/1kV 4x35mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 35 mm²
- Conductor diameter: 7.33 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.5 mm
- Outer Diameter: 26 mm
- Approximate weight: 1569 kg/km
Nexans HEPR-PVC 0.6/1kV 4x50mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 50 mm²
- Conductor diameter: 9.0 mm
- Nominal insulation thickness: 1.0 mm
- Protective Covering Nominal Thickness: 1.7 mm
- Outer Diameter: 31 mm
- Approximate weight: 2220 kg/km
Nexans HEPR-PVC 0.6/1kV 4x70mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 70 mm²
- Conductor diameter: 10.75 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.8 mm
- Outer Diameter: 36.5 mm
- Approximate weight: 3029 kg/km
Nexans HEPR-PVC 0.6/1kV 4x95mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 95 mm²
- Conductor diameter: 12.2 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.9 mm
- Outer Diameter: 40 mm
- Approximate weight: 4014 kg/km
Nexans HEPR-PVC 0.6/1kV 4x120mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 120 mm²
- Conductor diameter: 13.82 mm
- Nominal insulation thickness: 1.2 mm
- Protective Covering Nominal Thickness: 2.1 mm
- Outer Diameter: 45 mm
- Approximate weight: 5079 kg/km
Nexans HEPR-PVC 0.6/1kV 4x150mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 150 mm²
- Conductor diameter: 15.24 mm
- Nominal insulation thickness: 1.4 mm
- Protective Covering Nominal Thickness: 2.3 mm
- Outer Diameter: 50 mm
- Approximate weight: 6355 kg/km
Nexans HEPR-PVC 0.6/1kV 4x185mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 185 mm²
- Conductor diameter: 16.98 mm
- Nominal insulation thickness: 1.6 mm
- Protective Covering Nominal Thickness: 2.4 mm
- Outer Diameter: 55.5 mm
- Approximate weight: 7606 kg/km
Nexans HEPR-PVC 0.6/1kV 4x240mm2
Nexans ref.
- Number of cores: 4
- Conductor cross-section: 240 mm²
- Conductor diameter: 19.76 mm
- Nominal insulation thickness: 1.7 mm
- Protective Covering Nominal Thickness: 2.6 mm
- Outer Diameter: 63.5 mm
- Approximate weight: 10089 kg/km
Nexans HEPR-PVC 0.6/1kV 5x1.5mm2
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.5 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.1 mm
- Outer Diameter: 11 mm
- Approximate weight: 157.6 kg/km
Nexans HEPR-PVC 0.6/1kV 5x2.5mm2
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.97 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.1 mm
- Outer Diameter: 12 mm
- Approximate weight: 204.8 kg/km
Nexans HEPR-PVC 0.6/1kV 5x4mm2
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.45 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.2 mm
- Outer Diameter: 13.5 mm
- Approximate weight: 289.9 kg/km
Nexans HEPR-PVC 0.6/1kV 5x6mm2
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.0 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.2 mm
- Outer Diameter: 15 mm
- Approximate weight: 385.8 kg/km
Nexans HEPR-PVC 0.6/1kV 5x10mm2
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 10 mm²
- Conductor diameter: 3.9 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.3 mm
- Outer Diameter: 18 mm
- Approximate weight: 601.6 kg/km
Nexans HEPR-PVC 0.6/1kV 5x16mm2
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 16 mm²
- Conductor diameter: 4.93 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.4 mm
- Outer Diameter: 21 mm
- Approximate weight: 890.7 kg/km
Nexans HEPR-PVC 0.6/1kV 5x25mm2
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 25 mm²
- Conductor diameter: 6.16 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.5 mm
- Outer Diameter: 25.5 mm
- Approximate weight: 1366 kg/km
Nexans HEPR-PVC 0.6/1kV 5x35mm2
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 35 mm²
- Conductor diameter: 7.33 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.6 mm
- Outer Diameter: 29 mm
- Approximate weight: 1842 kg/km
Nexans HEPR-PVC 0.6/1kV 5x50mm2
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 50 mm²
- Conductor diameter: 9.0 mm
- Nominal insulation thickness: 1.0 mm
- Protective Covering Nominal Thickness: 1.8 mm
- Outer Diameter: 34.5 mm
- Approximate weight: 2625 kg/km
Nexans HEPR-PVC 0.6/1kV 5x70mm2
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 70 mm²
- Conductor diameter: 10.75 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.9 mm
- Outer Diameter: 40 mm
- Approximate weight: 3635 kg/km
Nexans HEPR-PVC 0.6/1kV 5x95mm2
Nexans ref.
- Number of cores: 5
- Conductor cross-section: 95 mm²
- Conductor diameter: 12.2 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 2.1 mm
- Outer Diameter: 45 mm
- Approximate weight: 4827 kg/km
Description
Description
Standards
-
NationalABNT NBR 6251 ; ABNT NBR 7286 ; ABNT NBR NM 280; ABNT NBR NM-IEC 60332-1
Application:
Nexans HEPR-PVC 0.6/1kV cable is the ideal choice for fixed installations requiring maximum flexibility and safety. This cable is perfect for residential, commercial and industrial buildings, as well as substations. Designed to meet the most diverse needs, it is suitable for general installations in outdoor conduits, whether in trays, racks or similar supports, as well as in profiles, building spaces and underground systems such as duct banks, following the recommendations of NBR 5410.
Construction:
1. Conductor: Made of bare copper wires, minimum conductivity 100% IACS, soft temper, meeting class 5 stranding.
2. Insulation: High-modulus ethylene-propylene-based thermosetting compound, HEPR for 90°C, meeting the physical requirements prescribed by NBR 7286.
3. Cover: Polyvinyl chloride (PVC), in black, meeting the physical requirements prescribed in NBR 6251, for type ST2.
Note: Where necessary, a polyvinyl chloride (PVC) filler is applied to multi-core cables.
Identification:
- 2 strands: black and light blue;
- 3 strands: black, light blue and white;
- 4 strands: black, light blue, white and red;
- 5 veins: black, white, red, light blue and green.
Note: Other colors can be evaluated on request.
Operating regime:
The thermal limits under operating conditions are in accordance with ABNT NBR 6251.
Permanent regime: 90ºC
Overload regime: 130ºC
Short-circuit regime: 250ºC
Note:
- Dimensions and parameters determined on the basis of nominal values, therefore subject to the tolerances laid down in the specifications and manufacturing variations.
- All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans, being subject to a systemic revision or update without any formal or previous communication, following the referenced standards.
Important:
1) OWNERSHIP OF TECHNICAL DOCUMENTATION: Ownership of drawings, plans, manuals, diagrams, schematics, information, documents, etc. relating to the products offered or supplied to the customer belongs to, and shall remain with, Nexans. Should the customer receive a copy of such documents, the customer agrees not to use such drawings or other documents without the prior express written authorization of Nexans.
2) CONFIDENTIALITY: The customer shall not disclose information relating to this technical documentation to third parties without Nexans' prior written permission, nor use such information for purposes other than those related to the execution of the proposal (if accepted). Without prejudice to the above, Nexans may disclose information to third parties that are part of the same economic group as Nexans, for the purposes of executing this proposal, if necessary.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Current-carrying capacities
2 loaded conductors;
Conductors and cables with thermosetting compounds (HEPR, XLPE);
Conductor temperature: 90°C;
Ambient temperature: 30°C
Conductor cross-section | ||||||||
---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
1.5 | 19 | 18.5 | 23 | 22 | 24 | 26 | 26 | 27 |
2.5 | 26 | 25 | 31 | 30 | 33 | 34 | 36 | 37 |
4.0 | 35 | 33 | 42 | 40 | 45 | 44 | 49 | 50 |
6.0 | 45 | 42 | 54 | 51 | 58 | 56 | 63 | 65 |
10.0 | 61 | 57 | 75 | 69 | 80 | 73 | 86 | 90 |
16.0 | 81 | 76 | 100 | 91 | 107 | 95 | 115 | 121 |
25.0 | 106 | 99 | 133 | 119 | 138 | 121 | 149 | 161 |
35.0 | 131 | 121 | 164 | 146 | 171 | 146 | 185 | 200 |
50.0 | 158 | 145 | 198 | 175 | 209 | 173 | 225 | 242 |
70.0 | 200 | 183 | 253 | 221 | 269 | 213 | 289 | 310 |
95.0 | 241 | 220 | 306 | 265 | 328 | 252 | 352 | 377 |
120.0 | 278 | 253 | 354 | 305 | 382 | 287 | 410 | 437 |
150.0 | 318 | 290 | 407 | 349 | 441 | 324 | 473 | 504 |
185.0 | 362 | 329 | 464 | 395 | 506 | 363 | 542 | 575 |
240.0 | 424 | 386 | 546 | 462 | 599 | 419 | 641 | 679 |
300.0 | 486 | 442 | 628 | 529 | 693 | 474 | 741 | 783 |
400.0 | 579 | 527 | 751 | 628 | 835 | 555 | 892 | 940 |
500.0 | 664 | 604 | 864 | 718 | 966 | 627 | 1030 | 1083 |
630.0 | 765 | 696 | 998 | 825 | 1122 | 711 | 1196 | 1254 |
A1 - Insulated conductors in circular section conduit embedded in thermally insulating wall |
A2 - Multi-core cable in circular section conduit embedded in thermally insulating wall |
B1 - Insulated conductors in circular section conduit on wooden wall |
B2 - Multi-core cable in circular section conduit on wooden wall |
C - Single-core cables or multi-core cable on wooden wall |
D - Multi-core cable in grounded conduit |
E - Multi-core outdoor cable |
F - Two Single-core cables |
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania