EASYCALC™

Determines a cable cross-section in 4 easy steps

What is EASYCALC™?

EASYCALC™ is a reliable cable section calculation program. It is a free-of-charge tool designed for the professional: electricians, installers, engineers, etc. with which you easily calculate the section of a cable length.

EASYCALC™ in 4 simple steps

Correct cable calculation takes into account the correction factors applicable for the installation. And so does EASYCALC™. In 4 simple steps, EASYCALC ™ requests the basic information and applies the relevant correction factors.

  1. Fill in the basic electrical data: amperage or power in kVA or kilowatts, cable length, voltage AC and the number of phases.
  2. Choose the desired cable type from the list and select the construction: indicate whether you need an earthing.
  3. Choose the installation method: above ground or underground, in trefoil or flat, ambient temperature etc.
  4. View the result and print it out to save with your files.

As an installer it’s sometimes difficult to gather data on the entire environmental factors of an installation. For example, you don’t always know the exact cosine φ or ambient temperature. In that case EASYCALC™ uses the default values from the standards. With each result, EASYCALC™ also recapitulates what values it has used to calculate. This allows you to test a few variants and thus also keep a clear trace of your section determination afterwards.

The result of the calculation is the theoretical section that can carry the requested current without risk of overloading (overheating) of the cable itself. In addition, the legislation must be applied, which may stipulate stricter conditions for protective devices, for example.

 

EASYCALC™ in 4 simple steps

Correct cable calculation takes into account the correction factors applicable for the installation. And so does EASYCALC™. In 4 simple steps, EASYCALC ™ requests the basic information and applies the relevant correction factors.

  1. Fill in the basic electrical data: amperage or power in kVA or kilowatts, cable length, voltage AC and the number of phases.
  2. Choose the desired cable type from the list and select the construction: indicate whether you need an earthing.
  3. Choose the installation method: above ground or underground, in trefoil or flat, ambient temperature etc.
  4. View the result and print it out to save with your files.

As an installer it’s sometimes difficult to gather data on the entire environmental factors of an installation. For example, you don’t always know the exact cosine φ or ambient temperature. In that case EASYCALC™ uses the default values from the standards. With each result, EASYCALC™ also recapitulates what values it has used to calculate. This allows you to test a few variants and thus also keep a clear trace of your section determination afterwards.

The result of the calculation is the theoretical section that can carry the requested current without risk of overloading (overheating) of the cable itself. In addition, the legislation must be applied, which may stipulate stricter conditions for protective devices, for example.

 

Straight to the tool:

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close