Nexans VFD HEPR-SHF1 0,6/1kV

Products

Nexans VFD HEPR-SHF1 0,6/1kV 3x2.5+2.5mm2

Nexans ref.

  • With smaller neutral conductor: No
  • Phase Conductor Cross Section: 2.5 mm²
  • Phase Conductor Diameter: 1.97 mm
  • Nominal insulation thickness: 0.7 mm
  • Protective Covering Nominal Thickness: 1.4 mm
  • Nominal outer diameter: 14.0 mm
  • Approximate weight: 294 kg/km
  • Conductor cross-section: 2.5 mm²
  • Neutral conductor section (when smaller): - mm²

 

Nexans VFD HEPR-SHF1 0,6/1kV 3x4+4mm2

Nexans ref.

  • With smaller neutral conductor: No
  • Phase Conductor Cross Section: 4 mm²
  • Phase Conductor Diameter: 2.45 mm
  • Nominal insulation thickness: 0.7 mm
  • Protective Covering Nominal Thickness: 1.4 mm
  • Nominal outer diameter: 15.5 mm
  • Approximate weight: 338.4 kg/km
  • Conductor cross-section: 4 mm²
  • Neutral conductor section (when smaller): - mm²

 

Nexans VFD HEPR-SHF1 0,6/1kV 3x6+6mm2

Nexans ref.

  • With smaller neutral conductor: No
  • Phase Conductor Cross Section: 6 mm²
  • Phase Conductor Diameter: 3 mm
  • Nominal insulation thickness: 0.7 mm
  • Protective Covering Nominal Thickness: 1.4 mm
  • Nominal outer diameter: 16.5 mm
  • Approximate weight: 436 kg/km
  • Conductor cross-section: 6 mm²
  • Neutral conductor section (when smaller): - mm²

 

Nexans VFD HEPR-SHF1 0,6/1kV 3x10+10mm2

Nexans ref.

  • With smaller neutral conductor: No
  • Phase Conductor Cross Section: 10 mm²
  • Phase Conductor Diameter: 3.9 mm
  • Nominal insulation thickness: 0.7 mm
  • Protective Covering Nominal Thickness: 1.4 mm
  • Nominal outer diameter: 19.0 mm
  • Approximate weight: 623.9 kg/km
  • Conductor cross-section: 10 mm²
  • Neutral conductor section (when smaller): - mm²

 

Nexans VFD HEPR-SHF1 0,6/1kV 3x16+16mm2

Nexans ref.

  • With smaller neutral conductor: No
  • Phase Conductor Cross Section: 16 mm²
  • Phase Conductor Diameter: 4.93 mm
  • Nominal insulation thickness: 0.7 mm
  • Protective Covering Nominal Thickness: 1.4 mm
  • Nominal outer diameter: 21.5 mm
  • Approximate weight: 877.6 kg/km
  • Conductor cross-section: 16 mm²
  • Neutral conductor section (when smaller): - mm²

 

Nexans VFD HEPR-SHF1 0,6/1kV 3x25+16mm2

Nexans ref.

  • With smaller neutral conductor: Yes
  • Phase Conductor Cross Section: 25 mm²
  • Phase Conductor Diameter: 6.16 mm
  • Nominal insulation thickness: 0.9 mm
  • Protective Covering Nominal Thickness: 1.5 mm
  • Nominal outer diameter: 25.0 mm
  • Approximate weight: 1299 kg/km
  • Conductor cross-section: 25 mm²
  • Neutral conductor section (when smaller): 16 mm²

 

Nexans VFD HEPR-SHF1 0,6/1kV 3x35+16mm2

Nexans ref.

  • With smaller neutral conductor: Yes
  • Phase Conductor Cross Section: 35 mm²
  • Phase Conductor Diameter: 7.33 mm
  • Nominal insulation thickness: 0.9 mm
  • Protective Covering Nominal Thickness: 1.5 mm
  • Nominal outer diameter: 28.0 mm
  • Approximate weight: 1549 kg/km
  • Conductor cross-section: 35 mm²
  • Neutral conductor section (when smaller): 16 mm²

 

Nexans VFD HEPR-SHF1 0,6/1kV 3x50+25mm2

Nexans ref.

  • With smaller neutral conductor: Yes
  • Phase Conductor Cross Section: 50 mm²
  • Phase Conductor Diameter: 9 mm
  • Nominal insulation thickness: 1.0 mm
  • Protective Covering Nominal Thickness: 1.7 mm
  • Nominal outer diameter: 32.5 mm
  • Approximate weight: 2059 kg/km
  • Conductor cross-section: 50 mm²
  • Neutral conductor section (when smaller): 25 mm²

 

Nexans VFD HEPR-SHF1 0,6/1kV 3x70+35mm2

Nexans ref.

  • With smaller neutral conductor: Yes
  • Phase Conductor Cross Section: 70 mm²
  • Phase Conductor Diameter: 10.75 mm
  • Nominal insulation thickness: 1.1 mm
  • Protective Covering Nominal Thickness: 1.8 mm
  • Nominal outer diameter: 38.5 mm
  • Approximate weight: 2894 kg/km
  • Conductor cross-section: 70 mm²
  • Neutral conductor section (when smaller): 35 mm²

 

Nexans VFD HEPR-SHF1 0,6/1kV 3x95+50mm2

Nexans ref.

  • With smaller neutral conductor: Yes
  • Phase Conductor Cross Section: 95 mm²
  • Phase Conductor Diameter: 12.2 mm
  • Nominal insulation thickness: 1.1 mm
  • Protective Covering Nominal Thickness: 1.9 mm
  • Nominal outer diameter: 42.0 mm
  • Approximate weight: 3803 kg/km
  • Conductor cross-section: 95 mm²
  • Neutral conductor section (when smaller): 50 mm²

 

Nexans VFD HEPR-SHF1 0,6/1kV 3x120+70mm2

Nexans ref.

  • With smaller neutral conductor: Yes
  • Phase Conductor Cross Section: 120 mm²
  • Phase Conductor Diameter: 13.82 mm
  • Nominal insulation thickness: 1.2 mm
  • Protective Covering Nominal Thickness: 2.1 mm
  • Nominal outer diameter: 47.0 mm
  • Approximate weight: 4845 kg/km
  • Conductor cross-section: 120 mm²
  • Neutral conductor section (when smaller): 70 mm²

 

Nexans VFD HEPR-SHF1 0,6/1kV 3x150+95mm2

Nexans ref.

  • With smaller neutral conductor: Yes
  • Phase Conductor Cross Section: 150 mm²
  • Phase Conductor Diameter: 15.24 mm
  • Nominal insulation thickness: 1.4 mm
  • Protective Covering Nominal Thickness: 2.3 mm
  • Nominal outer diameter: 51.5 mm
  • Approximate weight: 6138 kg/km
  • Conductor cross-section: 150 mm²
  • Neutral conductor section (when smaller): 95 mm²

 

Nexans VFD HEPR-SHF1 0,6/1kV 3x185+95mm2

Nexans ref.

  • With smaller neutral conductor: Yes
  • Phase Conductor Cross Section: 185 mm²
  • Phase Conductor Diameter: 16.98 mm
  • Nominal insulation thickness: 1.6 mm
  • Protective Covering Nominal Thickness: 2.4 mm
  • Nominal outer diameter: 56.5 mm
  • Approximate weight: 7190 kg/km
  • Conductor cross-section: 185 mm²
  • Neutral conductor section (when smaller): 95 mm²

 

Nexans VFD HEPR-SHF1 0,6/1kV 3x240+120mm2

Nexans ref.

  • With smaller neutral conductor: Yes
  • Phase Conductor Cross Section: 240 mm²
  • Phase Conductor Diameter: 19.76 mm
  • Nominal insulation thickness: 1.7 mm
  • Protective Covering Nominal Thickness: 2.6 mm
  • Nominal outer diameter: 65.0 mm
  • Approximate weight: 9687 kg/km
  • Conductor cross-section: 240 mm²
  • Neutral conductor section (when smaller): 120 mm²

 

Description

Description

Standards

  • Product
    ABNT NBR 7286 ; ABNT NBR NM 280
  • Installation
    ABNT NBR 5410

Aplication

Nexans VFD HEPR-SHF1 0.6/1kV cables are used in the field of industrial automation, where there is an increasing presence of electromagnetic noise that can affect the operation of electric motors. Frequency inverter cables are particularly recommended for supplying and interconnecting systems with frequency inverters, designed to withstand the highest voltage gradients, through the presence of harmonics and suppression of noise and electromagnetic interference, which are present in these types of circuits. The covering of this cable is a non-halogenated thermoplastic compound type SHF1 (LFH - Low Fire Hazard), in black colour. It is particularly recommended for environments where, in the event of a fire, there is a potential risk due to the concentration of people or contamination of food and equipment.

Construction

  1. Phase conductors: Made of bare copper wires with a minimum conductivity of 100% IACS, soft-tempered, complying with class 5 stranding.
  2. Insulation: High-modulus ethylene-propylene compound (HEPR), for a maximum temperature of 90ºC in continuous operation.
  3. Core: Made up of three insulated conductors twisted together.
  4. Inner sheath: Layer of non-halogenated thermoplastic polyolefin compound (SHF1) extruded over the assembly, acting as a padding for the neutral conductor.
  5. Neutral conductor: Bare copper wires, helically arranged, regularly distributed over the inner sheath, reduced equivalent section for sections greater than 16 mm², in accordance with ABNT NBR 5410..
  6. Shielding: Copper tape applied to the neutral conductor, covering 100 per cent of the cable core.
  7. Outer sheath: Extruded layer of non-halogenated thermoplastic polyolefin compound (SHF1).

Identification

Insulation in black, red and white.

Note: Other colors can be evaluated on request.

 

Operation

Thermal limits according to ABNT NBR 6251.

  • Continuous operation: 90°C
  • Overload operation: 130°C
  • Short-circuit condition: 250°C

Note:

  • Dimensions and parameters determined on the basis of nominal values, therefore subject to the tolerances laid down in the specifications and manufacturing variations.
  • All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans, being subject to a systemic revision or update without any formal or previous communication, following the referenced standards.

Important:

1) OWNERSHIP OF TECHNICAL DOCUMENTATION: Ownership of drawings, plans, manuals, diagrams, schematics, information, documents, etc. relating to the products offered or supplied to the customer belongs to, and shall remain with, Nexans. Should the customer receive a copy of such documents, the customer agrees not to use such drawings or other documents without the prior express written authorization of Nexans.

2) CONFIDENTIALITY: The customer shall not disclose information relating to this technical documentation to third parties without Nexans' prior written permission, nor use such information for purposes other than those related to the execution of the proposal (if accepted). Without prejudice to the above, Nexans may disclose information to third parties that are part of the same economic group as Nexans, for the purposes of executing this proposal, if necessary.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor flexibility
Flexible class 5
Insulation
HEPR
Inner sheath
SHF1
Outer sheath
SHF1
Colour
Black
Halogen free
Yes
With Green/Yellow core
No

Dimensional characteristics

Dimensional characteristics

Number of cores
4

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Reasonable
Cable flexibility
Regular

Usage characteristics

Usage characteristics

Ambient installation temperature, range
-5 ... 60 °C
Fire retardant
IEC 60332-3-24 (cat C)
Smoke density
Low
Max. conductor temperature in service
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
250 °C
Packaging
Reel

Resources

Resources

Current carrying capacity

Conductor temperature: 90 °C;

Ambient temperature: 30 °C.

Conductor cross-section
mm² Cu Cu Cu Cu
2.5 28.0 24.0 23.0 21.0
4.0 36.0 32.0 30.0 28.0
6.0 46.0 41.0 38.0 36.0
10.0 65.0 57.0 53.0 50.0
16.0 86.0 76.0 71.0 66.0
25.0 109.0 96.0 90.0 84.0
35.0 136.0 120.0 111.0 105.0
50.0 165.0 145.0 135.0 127.0
70.0 212.0 186.0 173.0 163.0
95.0 256.0 226.0 210.0 197.0
120.0 298.0 262.0 244.0 229.0
150.0 343.0 302.0 281.0 264.0
185.0 392.0 345.0 322.0 302.0
240.0 463.0 407.0 379.0 356.0
1 cable/circuit
2 cables/circuits in the same tray
3 cables/circuits in the same tray
4 cables/circuits in the same tray

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close