- Markets
- Products
- Services and solutions
- About Nexans
- People and Carreer
- News
- Certificates and Documents
- Nexans Insights
- Search
- Contact us
- Compare
- Sign in
All Aluminium Conductor - AAC (AWG Series)
All Aluminium Conductor - AAC (AWG Series)
Conductor formed exclusively by aluminium wires.
Read moreAAC Pansy
Nexans ref.
- Packaging: Cut to length (m)
- Type of cable: Pansy
- Conductor flexibility: -
- Conductor shape: RN
- Conductor cross-section (AWG/KCMIL): 1
- Conductor cross-section: 42.49 mm²
- Diameter of aluminium wires: 2.78 mm
- Conductor diameter: 8.34 mm
- Approximate weight: 117.1 kg/km
- Average geometric radius: 0.00302 m
- Nominal outer diameter: 8.34 mm
AAC Poppy
Nexans ref. 64332
- Packaging: Cut to length (30000m)
- Type of cable: Poppy
- Conductor flexibility: Class AA
- Conductor shape: Circular non compacted
- Conductor cross-section (AWG/KCMIL): 1/0
- Conductor cross-section: 53.52 mm²
- Diameter of aluminium wires: 3.12 mm
- Conductor diameter: 9.36 mm
- Approximate weight: 147.8 kg/km
- Average geometric radius: 0.00339 m
- Nominal outer diameter: 9.36 mm
AAC Iris
Nexans ref. 64446
- Packaging: Cut to length (20000m)
- Type of cable: Iris
- Conductor flexibility: Class A
- Conductor shape: Circular non compacted
- Conductor cross-section (AWG/KCMIL): 2
- Conductor cross-section: 33.54 mm²
- Diameter of aluminium wires: 2.47 mm
- Conductor diameter: 7.41 mm
- Approximate weight: 92.63 kg/km
- Average geometric radius: 0.00269 m
- Nominal outer diameter: 7.41 mm
AAC Aster
Nexans ref. 64447
- Packaging: Cut to length (15000m)
- Type of cable: Aster
- Conductor flexibility: Class AA
- Conductor shape: Circular non compacted
- Conductor cross-section (AWG/KCMIL): 2/0
- Conductor cross-section: 67.35 mm²
- Diameter of aluminium wires: 3.5 mm
- Conductor diameter: 10.5 mm
- Approximate weight: 186.1 kg/km
- Average geometric radius: 0.00381 m
- Nominal outer diameter: 10.5 mm
AAC Lily
Nexans ref.
- Packaging: Cut to length (m)
- Type of cable: Lily
- Conductor flexibility: -
- Conductor shape: RN
- Conductor cross-section (AWG/KCMIL): 3
- Conductor cross-section: 26.61 mm²
- Diameter of aluminium wires: 2.2 mm
- Conductor diameter: 6.6 mm
- Approximate weight: 73.4 kg/km
- Average geometric radius: 0.0024 m
- Nominal outer diameter: 6.6 mm
AAC Phlox
Nexans ref. 64448
- Packaging: Cut to length (20000m)
- Type of cable: Phlox
- Conductor flexibility: Class AA
- Conductor shape: Circular non compacted
- Conductor cross-section (AWG/KCMIL): 3/0
- Conductor cross-section: 84.91 mm²
- Diameter of aluminium wires: 3.93 mm
- Conductor diameter: 11.79 mm
- Approximate weight: 234.5 kg/km
- Average geometric radius: 0.00428 m
- Nominal outer diameter: 11.79 mm
AAC Rose
Nexans ref. 64445
- Packaging: Cut to length (m)
- Type of cable: Rose
- Conductor flexibility: Class A
- Conductor shape: Circular non compacted
- Conductor cross-section (AWG/KCMIL): 4
- Conductor cross-section: 21.12 mm²
- Diameter of aluminium wires: 1.96 mm
- Conductor diameter: 5.88 mm
- Approximate weight: 58.31 kg/km
- Average geometric radius: 0.00213 m
- Nominal outer diameter: 5.88 mm
AAC Oxlip
Nexans ref. 64449
- Packaging: Cut to length (m)
- Type of cable: Oxlip
- Conductor flexibility: Class AA
- Conductor shape: Circular non compacted
- Conductor cross-section (AWG/KCMIL): 4/0
- Conductor cross-section: 107.41 mm²
- Diameter of aluminium wires: 4.42 mm
- Conductor diameter: 13.26 mm
- Approximate weight: 296.6 kg/km
- Average geometric radius: 0.00481 m
- Nominal outer diameter: 13.26 mm
AAC Peachbell
Nexans ref.
- Packaging: Cut to length (m)
- Type of cable: Peachbell
- Conductor flexibility: -
- Conductor shape: -
- Conductor cross-section (AWG/KCMIL): 6
- Conductor cross-section: 13.21 mm²
- Diameter of aluminium wires: 1.55 mm
- Conductor diameter: 4.65 mm
- Approximate weight: 36.4 kg/km
- Average geometric radius: 0.00169 m
- Nominal outer diameter: 4.65 mm
Description
Description
Standards
-
ProductABNT NBR 7271/88; ASTM B 231
It is an homogeneous conductor stranded with Aluminium 1350, Class AA for bare conductors used in overhead lines.
APPLICATIONS
AAC is usually as bare cable for primary and secondary distribution lines with short spans where high mechanical strength is not required. However due to be an Aluminium 1350 homogeneous conductor, the Ampacity is well optimized.
CONSTRUCTION
AAC is concentrically stranded conductor with one or more layers of Aluminium wire hard-drawn 1350-H19. The number of wires depends basically on the electrical requirements that will define the size.
Conditions for Ampacity calculation
Conductor temperature = 75 °C;
Room temperature = 25 °C;
Wind speed = 1 m/sec, sunny.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Mechanical characteristics
Mechanical characteristics
Resources
Resources
Documentation
Related products
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania