All Aluminium Conductor - AAC (AWG Series)

Products

AAC Pansy

Nexans ref.

  • Packaging: Cut to length (m)
  • Type of cable: Pansy
  • Conductor flexibility: -
  • Conductor shape: RN
  • Conductor cross-section (AWG/KCMIL): 1
  • Conductor cross-section: 42.49 mm²
  • Diameter of aluminium wires: 2.78 mm
  • Conductor diameter: 8.34 mm
  • Approximate weight: 117.1 kg/km
  • Average geometric radius: 0.00302 m
  • Nominal outer diameter: 8.34 mm

 

AAC Poppy

Nexans ref. 64332

  • Packaging: Cut to length (30000m)
  • Type of cable: Poppy
  • Conductor flexibility: Class AA
  • Conductor shape: Circular non compacted
  • Conductor cross-section (AWG/KCMIL): 1/0
  • Conductor cross-section: 53.52 mm²
  • Diameter of aluminium wires: 3.12 mm
  • Conductor diameter: 9.36 mm
  • Approximate weight: 147.8 kg/km
  • Average geometric radius: 0.00339 m
  • Nominal outer diameter: 9.36 mm

 

AAC Iris

Nexans ref. 64446

  • Packaging: Cut to length (20000m)
  • Type of cable: Iris
  • Conductor flexibility: Class A
  • Conductor shape: Circular non compacted
  • Conductor cross-section (AWG/KCMIL): 2
  • Conductor cross-section: 33.54 mm²
  • Diameter of aluminium wires: 2.47 mm
  • Conductor diameter: 7.41 mm
  • Approximate weight: 92.63 kg/km
  • Average geometric radius: 0.00269 m
  • Nominal outer diameter: 7.41 mm

 

AAC Aster

Nexans ref. 64447

  • Packaging: Cut to length (15000m)
  • Type of cable: Aster
  • Conductor flexibility: Class AA
  • Conductor shape: Circular non compacted
  • Conductor cross-section (AWG/KCMIL): 2/0
  • Conductor cross-section: 67.35 mm²
  • Diameter of aluminium wires: 3.5 mm
  • Conductor diameter: 10.5 mm
  • Approximate weight: 186.1 kg/km
  • Average geometric radius: 0.00381 m
  • Nominal outer diameter: 10.5 mm

 

AAC Lily

Nexans ref.

  • Packaging: Cut to length (m)
  • Type of cable: Lily
  • Conductor flexibility: -
  • Conductor shape: RN
  • Conductor cross-section (AWG/KCMIL): 3
  • Conductor cross-section: 26.61 mm²
  • Diameter of aluminium wires: 2.2 mm
  • Conductor diameter: 6.6 mm
  • Approximate weight: 73.4 kg/km
  • Average geometric radius: 0.0024 m
  • Nominal outer diameter: 6.6 mm

 

AAC Phlox

Nexans ref. 64448

  • Packaging: Cut to length (20000m)
  • Type of cable: Phlox
  • Conductor flexibility: Class AA
  • Conductor shape: Circular non compacted
  • Conductor cross-section (AWG/KCMIL): 3/0
  • Conductor cross-section: 84.91 mm²
  • Diameter of aluminium wires: 3.93 mm
  • Conductor diameter: 11.79 mm
  • Approximate weight: 234.5 kg/km
  • Average geometric radius: 0.00428 m
  • Nominal outer diameter: 11.79 mm

 

AAC Rose

Nexans ref. 64445

  • Packaging: Cut to length (m)
  • Type of cable: Rose
  • Conductor flexibility: Class A
  • Conductor shape: Circular non compacted
  • Conductor cross-section (AWG/KCMIL): 4
  • Conductor cross-section: 21.12 mm²
  • Diameter of aluminium wires: 1.96 mm
  • Conductor diameter: 5.88 mm
  • Approximate weight: 58.31 kg/km
  • Average geometric radius: 0.00213 m
  • Nominal outer diameter: 5.88 mm

 

AAC Oxlip

Nexans ref. 64449

  • Packaging: Cut to length (m)
  • Type of cable: Oxlip
  • Conductor flexibility: Class AA
  • Conductor shape: Circular non compacted
  • Conductor cross-section (AWG/KCMIL): 4/0
  • Conductor cross-section: 107.41 mm²
  • Diameter of aluminium wires: 4.42 mm
  • Conductor diameter: 13.26 mm
  • Approximate weight: 296.6 kg/km
  • Average geometric radius: 0.00481 m
  • Nominal outer diameter: 13.26 mm

 

AAC Peachbell

Nexans ref.

  • Packaging: Cut to length (m)
  • Type of cable: Peachbell
  • Conductor flexibility: -
  • Conductor shape: -
  • Conductor cross-section (AWG/KCMIL): 6
  • Conductor cross-section: 13.21 mm²
  • Diameter of aluminium wires: 1.55 mm
  • Conductor diameter: 4.65 mm
  • Approximate weight: 36.4 kg/km
  • Average geometric radius: 0.00169 m
  • Nominal outer diameter: 4.65 mm

 

Description

Description

Standards

  • National
    ABNT NBR 7271/88; ASTM B 231

It is an homogeneous conductor stranded with Aluminium 1350, Class AA for bare conductors used in overhead lines.

 

APPLICATIONS

AAC is usually as bare cable for primary and secondary distribution lines with short spans where high mechanical strength is not required. However due to be an Aluminium 1350 homogeneous conductor, the Ampacity is well optimized.

 

CONSTRUCTION

AAC is concentrically stranded conductor with one or more layers of Aluminium wire hard-drawn 1350-H19. The number of wires depends basically on the electrical requirements that will define the size.

 

Conditions for Ampacity calculation

Conductor temperature = 75 °C;

Room temperature = 25 °C;

Wind speed = 1 m/sec, sunny.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Type of conductor
Circular, stranded
With smaller neutral conductor
-

Dimensional characteristics

Dimensional characteristics

Number of aluminium wires
7
Number of cores
1
Number of round wires
7

Mechanical characteristics

Mechanical characteristics

Hardness type
1350-H19

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close