- Markets
- Products
- Services and solutions
- About Nexans
- People and Carreer
- News
- Certificates and Documents
- Nexans Insights
- Search
- Contact us
- Compare
- Sign in
Nexans VFD HEPR-PVC 0,6/1kV
Nexans VFD HEPR-PVC 0,6/1kV
Introducing Nexans VFD HEPR-PVC 0.6/1kV cables (formerly FIBEP NC-F), with three flexible class 5 copper conductors, insulated with HEPR, copper armouring and PVC covering. They range from 2.5 to 240 mm² and are ideal for industrial automation and electric motors, protecting against electromagnetic noise. See technical details below:
Read moreNexans VFD HEPR-PVC 0,6/1kV 3x2.5+2.5mm2
Nexans ref.
- With smaller neutral conductor: No
- Phase Conductor Cross Section: 2.5 mm²
- Phase Conductor Diameter: 1.97 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.4 mm
- Nominal outer diameter: 14.5 mm
- Approximate weight: 280.1 kg/km
- Conductor cross-section: 2.5 mm²
- Neutral conductor section (when smaller): - mm²
Nexans VFD HEPR-PVC 0,6/1kV 3x4+4mm2
Nexans ref.
- With smaller neutral conductor: No
- Phase Conductor Cross Section: 4 mm²
- Phase Conductor Diameter: 2.45 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.4 mm
- Nominal outer diameter: 15.5 mm
- Approximate weight: 350.9 kg/km
- Conductor cross-section: 4 mm²
- Neutral conductor section (when smaller): - mm²
Nexans VFD HEPR-PVC 0,6/1kV 3x6+6mm2
Nexans ref.
- With smaller neutral conductor: No
- Phase Conductor Cross Section: 6 mm²
- Phase Conductor Diameter: 3 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.4 mm
- Nominal outer diameter: 16.5 mm
- Approximate weight: 443.7 kg/km
- Conductor cross-section: 6 mm²
- Neutral conductor section (when smaller): - mm²
Nexans VFD HEPR-PVC 0,6/1kV 3x10+10mm2
Nexans ref.
- With smaller neutral conductor: No
- Phase Conductor Cross Section: 10 mm²
- Phase Conductor Diameter: 3.9 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.4 mm
- Nominal outer diameter: 19.0 mm
- Approximate weight: 649.4 kg/km
- Conductor cross-section: 10 mm²
- Neutral conductor section (when smaller): - mm²
Nexans VFD HEPR-PVC 0,6/1kV 3x16+16mm2
Nexans ref.
- With smaller neutral conductor: No
- Phase Conductor Cross Section: 16 mm²
- Phase Conductor Diameter: 4.93 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.4 mm
- Nominal outer diameter: 21.0 mm
- Approximate weight: 913.7 kg/km
- Conductor cross-section: 16 mm²
- Neutral conductor section (when smaller): - mm²
Nexans VFD HEPR-PVC 0,6/1kV 3x25+16mm2
Nexans ref.
- With smaller neutral conductor: Yes
- Phase Conductor Cross Section: 25 mm²
- Phase Conductor Diameter: 6.16 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.5 mm
- Nominal outer diameter: 25.0 mm
- Approximate weight: 1357 kg/km
- Conductor cross-section: 25 mm²
- Neutral conductor section (when smaller): 16 mm²
Nexans VFD HEPR-PVC 0,6/1kV 3x35+16mm2
Nexans ref.
- With smaller neutral conductor: Yes
- Phase Conductor Cross Section: 35 mm²
- Phase Conductor Diameter: 7.33 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.5 mm
- Nominal outer diameter: 27.5 mm
- Approximate weight: 1621 kg/km
- Conductor cross-section: 35 mm²
- Neutral conductor section (when smaller): 16 mm²
Nexans VFD HEPR-PVC 0,6/1kV 3x50+25mm2
Nexans ref.
- With smaller neutral conductor: Yes
- Phase Conductor Cross Section: 50 mm²
- Phase Conductor Diameter: 9 mm
- Nominal insulation thickness: 1.0 mm
- Protective Covering Nominal Thickness: 1.7 mm
- Nominal outer diameter: 32.5 mm
- Approximate weight: 2144 kg/km
- Conductor cross-section: 50 mm²
- Neutral conductor section (when smaller): 25 mm²
Nexans VFD HEPR-PVC 0,6/1kV 3x70+35mm2
Nexans ref.
- With smaller neutral conductor: Yes
- Phase Conductor Cross Section: 70 mm²
- Phase Conductor Diameter: 10.75 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.8 mm
- Nominal outer diameter: 39.0 mm
- Approximate weight: 2938 kg/km
- Conductor cross-section: 70 mm²
- Neutral conductor section (when smaller): 35 mm²
Nexans VFD HEPR-PVC 0,6/1kV 3x95+50mm2
Nexans ref.
- With smaller neutral conductor: Yes
- Phase Conductor Cross Section: 95 mm²
- Phase Conductor Diameter: 12.2 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.9 mm
- Nominal outer diameter: 42.5 mm
- Approximate weight: 3863 kg/km
- Conductor cross-section: 95 mm²
- Neutral conductor section (when smaller): 50 mm²
Nexans VFD HEPR-PVC 0,6/1kV 3x120+70mm2
Nexans ref.
- With smaller neutral conductor: Yes
- Phase Conductor Cross Section: 120 mm²
- Phase Conductor Diameter: 13.82 mm
- Nominal insulation thickness: 1.2 mm
- Protective Covering Nominal Thickness: 2.1 mm
- Nominal outer diameter: 47.0 mm
- Approximate weight: 4922 kg/km
- Conductor cross-section: 120 mm²
- Neutral conductor section (when smaller): 70 mm²
Nexans VFD HEPR-PVC 0,6/1kV 3x150+95mm2
Nexans ref.
- With smaller neutral conductor: Yes
- Phase Conductor Cross Section: 150 mm²
- Phase Conductor Diameter: 15.24 mm
- Nominal insulation thickness: 1.4 mm
- Protective Covering Nominal Thickness: 2.3 mm
- Nominal outer diameter: 51.5 mm
- Approximate weight: 6210 kg/km
- Conductor cross-section: 150 mm²
- Neutral conductor section (when smaller): 95 mm²
Nexans VFD HEPR-PVC 0,6/1kV 3x185+95mm2
Nexans ref.
- With smaller neutral conductor: Yes
- Phase Conductor Cross Section: 185 mm²
- Phase Conductor Diameter: 16.98 mm
- Nominal insulation thickness: 1.6 mm
- Protective Covering Nominal Thickness: 2.4 mm
- Nominal outer diameter: 56.5 mm
- Approximate weight: 7306 kg/km
- Conductor cross-section: 185 mm²
- Neutral conductor section (when smaller): 95 mm²
Nexans VFD HEPR-PVC 0,6/1kV 3x240+120mm2
Nexans ref.
- With smaller neutral conductor: Yes
- Phase Conductor Cross Section: 240 mm²
- Phase Conductor Diameter: 19.76 mm
- Nominal insulation thickness: 1.7 mm
- Protective Covering Nominal Thickness: 2.6 mm
- Nominal outer diameter: 65.0 mm
- Approximate weight: 9783 kg/km
- Conductor cross-section: 240 mm²
- Neutral conductor section (when smaller): 120 mm²
Description
Description
Standards
-
ProductABNT NBR 7286 ; ABNT NBR NM 280
-
InstallationABNT NBR 5410
Aplication
Nexans VFD HEPR-PVC 0.6/1kV cables are used in the field of industrial automation, where there is an increasing presence of electromagnetic noise that can affect the operation of electric motors. Frequency inverter cables are particularly recommended for supplying and interconnecting systems with frequency inverters, designed to withstand the highest voltage gradients, through the presence of harmonics and suppression of noise and electromagnetic interference, which are present in these types of circuits.
Construction
- Phase conductors: Made of bare copper wires with a minimum conductivity of 100% IACS, soft-tempered, complying with class 5 stranding.
- Insulation: High-modulus ethylene-propylene compound (HEPR), for a maximum temperature of 90ºC in continuous operation.
- Core: Made up of three insulated conductors twisted together.
- Inner sheath: PVC-Polyvinyl Chloride layer extruded on the twisted conductors, serving as cushioning for the neutral conductor.
- Neutral conductor: Bare copper wires, helically arranged, regularly distributed over the inner sheath, reduced equivalent section for sections greater than 16 mm², in accordance with ABNT NBR 5410..
- Shielding: Copper tape applied to the neutral conductor, covering 100 per cent of the cable core.
- Outer sheath: Extruded layer of polyvinyl chloride (PVC ST2).
Identification
Insulation in black, white and light-blue colors.
Operation
Thermal limits according to ABNT NBR 6251.
- Continuous operation: 90°C
- Overload operation: 130°C
- Short-circuit condition: 250°C
Note:
- Dimensions and parameters determined on the basis of nominal values, therefore subject to the tolerances laid down in the specifications and manufacturing variations.
- All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans, being subject to a systemic revision or update without any formal or previous communication, following the referenced standards.
Important:
1) OWNERSHIP OF TECHNICAL DOCUMENTATION: Ownership of drawings, plans, manuals, diagrams, schematics, information, documents, etc. relating to the products offered or supplied to the customer belongs to, and shall remain with, Nexans. Should the customer receive a copy of such documents, the customer agrees not to use such drawings or other documents without the prior express written authorization of Nexans.
2) CONFIDENTIALITY: The customer shall not disclose information relating to this technical documentation to third parties without Nexans' prior written permission, nor use such information for purposes other than those related to the execution of the proposal (if accepted). Without prejudice to the above, Nexans may disclose information to third parties that are part of the same economic group as Nexans, for the purposes of executing this proposal, if necessary.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Current carrying capacity
Conductor temperature: 90 °C;
Ambient temperature: 30 °C.
Conductor cross-section | ||||
---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu |
2.5 | 28.0 | 24.0 | 23.0 | 21.0 |
4.0 | 36.0 | 32.0 | 30.0 | 28.0 |
6.0 | 46.0 | 41.0 | 38.0 | 36.0 |
10.0 | 65.0 | 57.0 | 53.0 | 50.0 |
16.0 | 86.0 | 76.0 | 71.0 | 66.0 |
25.0 | 109.0 | 96.0 | 90.0 | 84.0 |
35.0 | 136.0 | 120.0 | 111.0 | 105.0 |
50.0 | 165.0 | 145.0 | 135.0 | 127.0 |
70.0 | 212.0 | 186.0 | 173.0 | 163.0 |
95.0 | 256.0 | 226.0 | 210.0 | 197.0 |
120.0 | 298.0 | 262.0 | 244.0 | 229.0 |
150.0 | 343.0 | 302.0 | 281.0 | 264.0 |
185.0 | 392.0 | 345.0 | 322.0 | 302.0 |
240.0 | 463.0 | 407.0 | 379.0 | 356.0 |
1 cable/circuit |
2 cables/circuits in the same tray |
3 cables/circuits in the same tray |
4 cables/circuits in the same tray |
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania