Nexans EPR105-PVC AL 20/35kV

Products

Nexans EPR105-PVC AL 20/35kV 1x50mm²

Nexans ref.

  • Conductor cross-section: 50 mm²
  • Conductor diameter: 8.05 mm
  • Nominal insulation thickness: 7.5 mm
  • Diameter over insulation: 27.0 mm
  • Protective Covering Nominal Thickness: 1.8 mm
  • Outer Diameter: 33 mm
  • Approximate weight: 1105 kg/km

 

Nexans EPR105-PVC AL 20/35kV 1x70mm²

Nexans ref.

  • Conductor cross-section: 70 mm²
  • Conductor diameter: 9.7 mm
  • Nominal insulation thickness: 7.5 mm
  • Diameter over insulation: 27.0 mm
  • Protective Covering Nominal Thickness: 1.8 mm
  • Outer Diameter: 33 mm
  • Approximate weight: 1151 kg/km

 

Nexans EPR105-PVC AL 20/35kV 1x95mm²

Nexans ref.

  • Conductor cross-section: 95 mm²
  • Conductor diameter: 11.47 mm
  • Nominal insulation thickness: 7.5 mm
  • Diameter over insulation: 29.0 mm
  • Protective Covering Nominal Thickness: 1.8 mm
  • Outer Diameter: 35 mm
  • Approximate weight: 1298 kg/km

 

Nexans EPR105-PVC AL 20/35kV 1x120mm²

Nexans ref.

  • Conductor cross-section: 120 mm²
  • Conductor diameter: 12.95 mm
  • Nominal insulation thickness: 7.5 mm
  • Diameter over insulation: 30.0 mm
  • Protective Covering Nominal Thickness: 1.9 mm
  • Outer Diameter: 36.5 mm
  • Approximate weight: 1444 kg/km

 

Nexans EPR105-PVC AL 20/35kV 1x150mm²

Nexans ref.

  • Conductor cross-section: 150 mm²
  • Conductor diameter: 14.2 mm
  • Nominal insulation thickness: 7.5 mm
  • Diameter over insulation: 31.5 mm
  • Protective Covering Nominal Thickness: 1.9 mm
  • Outer Diameter: 38 mm
  • Approximate weight: 1564 kg/km

 

Nexans EPR105-PVC AL 20/35kV 1x185mm²

Nexans ref.

  • Conductor cross-section: 185 mm²
  • Conductor diameter: 15.8 mm
  • Nominal insulation thickness: 6.5 mm
  • Diameter over insulation: 31.5 mm
  • Protective Covering Nominal Thickness: 1.9 mm
  • Outer Diameter: 38 mm
  • Approximate weight: 1575 kg/km

 

Nexans EPR105-PVC AL 20/35kV 1x240mm²

Nexans ref.

  • Conductor cross-section: 240 mm²
  • Conductor diameter: 18.0 mm
  • Nominal insulation thickness: 6.5 mm
  • Diameter over insulation: 33.0 mm
  • Protective Covering Nominal Thickness: 2 mm
  • Outer Diameter: 40 mm
  • Approximate weight: 1839 kg/km

 

Nexans EPR105-PVC AL 20/35kV 1x300mm²

Nexans ref.

  • Conductor cross-section: 300 mm²
  • Conductor diameter: 20.1 mm
  • Nominal insulation thickness: 6.5 mm
  • Diameter over insulation: 35.5 mm
  • Protective Covering Nominal Thickness: 2.1 mm
  • Outer Diameter: 43 mm
  • Approximate weight: 2121 kg/km

 

Nexans EPR105-PVC AL 20/35kV 1x400mm²

Nexans ref.

  • Conductor cross-section: 400 mm²
  • Conductor diameter: 23.1 mm
  • Nominal insulation thickness: 6.5 mm
  • Diameter over insulation: 38.5 mm
  • Protective Covering Nominal Thickness: 2.2 mm
  • Outer Diameter: 45.5 mm
  • Approximate weight: 2474 kg/km

 

Nexans EPR105-PVC AL 20/35kV 1x500mm²

Nexans ref.

  • Conductor cross-section: 500 mm²
  • Conductor diameter: 26.4 mm
  • Nominal insulation thickness: 6.5 mm
  • Diameter over insulation: 43.0 mm
  • Protective Covering Nominal Thickness: 2.3 mm
  • Outer Diameter: 50 mm
  • Approximate weight: 2997 kg/km

 

Description

Description

Standards

  • National
    ABNT NBR 14039; ABNT NBR 6251 ; ABNT NBR 7286 ; ABNT NBR NM 280

Application:

Nexans EPR105-PVC AL cables are ideal for applications in insulated power supply and distribution circuits in substations, industrial and commercial installations, where cables with aluminium conductors are required. They can be installed in a variety of conditions, including outdoors, in conduits, ducts, underground installations, duct banks or trays. Compared to conventional EPR, HEPR or XLPE insulated cables, which have a maximum conductor temperature of 90 °C, Nexans EPR105-PVC AL cables can operate with a continuous conductor temperature of up to 105 °C, resulting in an increased current-carrying capacity. In addition, they have a coordinated insulation thickness, in accordance with NBR 6251, which results in reduced external dimensions compared to conventional cables insulated in EPR, HEPR or XLPE.

 

 

 

Construction:

1.Conductor: Formed of aluminum wires, round compacted, class 2 stranding, according to NBR NM 280.

2.Conductor shielding: Extruded semiconductor thermosetting compound.

3.Insulation: Ethylene propylene rubber thermosetting compound (EPR 105) for an operating temperature of 105 °C in the conductor, meeting the physical requirements prescribed by NBR 6251.

4.Insulation shielding: Non-metallic shielding based on extruded semiconductor thermosetting compound that is easy to remove when cold and manufactured using a triple extrusion process and a nitrogen dry-curing system.

5.Metallic shield: Made up of copper wires, helically applied to the insulation shield, with a minimum section of 6 mm2 in accordance with NBR 6251. For different shielding sections, ask for prior consultation.

6.Cover: Polyvinyl chloride (PVC) thermoplastic compound in black, meeting the physical requirements prescribed by NBR 6251, type ST2.

 

 

 

Identification:

They are supplied in black with sequential marking of the footage.

 

 

 

Operating regime:

The thermal limits under operating conditions are in accordance with ABNT NBR 6251.

Permanent regime: 105ºC

Overload regime: 140ºC

Short-circuit regime: 250ºC

Note:

  • Dimensions and parameters determined on the basis of nominal values, therefore subject to the tolerances laid down in the specifications and manufacturing variations.
  • All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans, being subject to a systemic revision or update without any formal or previous communication, following the referenced standards.

Important:

1) OWNERSHIP OF TECHNICAL DOCUMENTATION: Ownership of drawings, plans, manuals, diagrams, schematics, information, documents, etc. relating to the products offered or supplied to the customer belongs to, and shall remain with, Nexans. Should the customer receive a copy of such documents, the customer agrees not to use such drawings or other documents without the prior express written authorization of Nexans.

2) CONFIDENTIALITY: The customer shall not disclose information relating to this technical documentation to third parties without Nexans' prior written permission, nor use such information for purposes other than those related to the execution of the proposal (if accepted). Without prejudice to the above, Nexans may disclose information to third parties that are part of the same economic group as Nexans, for the purposes of executing this proposal, if necessary.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor flexibility
Stranded class 2
Conductor shape
Round, stranded and compacted
Insulation
EPR 105
Outer sheath
PVC ST2
Screen
Copper wires / 6mm²
Material of the external semi-conductor
Extruded
Material of the inner semi-conductor
Extruded
Colour
Black
Lead free
Yes

Dimensional characteristics

Dimensional characteristics

Number of cores
1
Screen section
6 mm²

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
20/35 kV

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Bending factor when laying
12 (xD)
Flame retardant
IEC 60332-1
Ambient installation temperature, range
-5 ... 60 °C
Weather resistance
Good
Max. conductor temperature in service
105 °C
Overload maximum core temperature
140 °C
Short-circuit max. conductor temperature
250 °C
Packaging
Drum
Chemical resistance
Good

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error