Nexans FORTIS TR XLPE-PE AL 20/35kV 1x70mm2
Nexans FORTIS TR XLPE-PE AL 20/35kV 1x70mm2
Nexans FORTIS TR XLPE-PE AL medium-voltage cable consists of a compact round aluminum conductor, locked, class 2 stranding, according to NBR NM 280 (IEC 60228), extruded semiconductor layers, insulation in special cross-linked polyethylene compound resistant to arborescence - type TR XLPE, of great thermal stability for operating temperature in permanent regime of up to 90°C, metallic shielding of the blocked type, made up of helically applied bare copper wires with a minimum cross-section of 16 mm2, a core with protection against termite attack consisting of a mechanical barrier and an outer cover made of a thermoplastic compound based on polyethylene type ST7. The FORTIS® solution offers protection against termites by means of a repellent barrier and a mechanical barrier that does not affect the bending radius of the cables and does not impact on the integrity of the shielding wires, facilitating the handling, installation and assembly of accessories. Patent PCT/FR2023/000104.
Read moreDescription
Description
Standards
-
NationalABNT NBR 7287 ; ABNT NBR NM 280
Application:
Nexans FORTIS TR XLPE-PE AL cable is especially suitable for solar parks in northeastern Brazil, where the presence of termites damages buried cables and with a padding system and metal shielding, they are specifically designed for direct buried installations, as established by NBR 14039, resisting the most severe installation conditions and load cycles typical of renewable energy sources.
Construction:
1. Conductor: Formed of aluminum wires, round compacted, blocked against longitudinal water penetration, class 2 stranding, according to NBR NM 280.
2. Conductor shielding: Extruded thermosetting semiconductor compound.
3. Insulation: Layer of thermosetting compound based on cross-linked polyethylene resistant to arborescence - type TR XLPE, of great thermal stability for operating temperature in permanent regime of up to 90ºC, meeting the physical requirements prescribed by NBR 6251.
4. Insulation shielding: Non-metallic shielding based on semiconductor extruded thermosetting compound, free-strippable type.
5. Mechanical barrier / termite protection: Consists of a physical barrier to protect the core of the cable, guaranteeing the integrity and performance of the dielectric system, which allows operational continuity in accordance with the cable's original design. The mechanical reinforcement barrier, which prevents invasive agents from getting through and consequently exposing or even damaging the dielectric, is consolidated by a double layer of tape (one made of copper and the other of laminated binding material) applied helically so as not to compromise flexibility or minimum bending radius, not generating additional electrical losses and without compromising or causing environmental impacts, guaranteeing the recycling cycle and the Product Environmental Profile - PEP of FORTIS TR XLPE-PE AL cables, in accordance with NEXANS environmental policy.
6. Metallic shield: Consists of a crown of bare copper wires, blocked against longitudinal water penetration and connected to the metallic barrier for the equipotentialization of the different protections, resulting in a minimum shield section of 16mm².
7. Cover: Extruded layer of thermoplastic polyethylene (PE) type ST7, FORTIS, acting as a first barrier with repellent additive, in black, with high mechanical characteristics, impermeability and reduced coefficient of friction and with characteristics in accordance with specification NBR 6251.
Identification:
They are supplied in black with sequential marking of footage.
Operating regime:
The thermal limits in operating regime are in accordance with ABNT NBR 6251.
Permanent regime: 90ºC
Overload regime: 130ºC
Short-circuit regime: 250ºC
Note:
- Dimensions and parameters determined on the basis of nominal values, therefore subject to the tolerances laid down in the specifications and manufacturing variations.
- All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans, being subject to a systemic revision or update without any formal or previous communication, following the referenced standards.
Important:
1) OWNERSHIP OF TECHNICAL DOCUMENTATION: Ownership of drawings, plans, manuals, diagrams, schematics, information, documents, etc. relating to the products offered or supplied to the customer belongs to, and shall remain with, Nexans. Should the customer receive a copy of such documents, the customer agrees not to use such drawings or other documents without the prior express written authorization of Nexans.
2) CONFIDENTIALITY: The customer shall not disclose information relating to this technical documentation to third parties without Nexans' prior written permission, nor use such information for purposes other than those related to the execution of the proposal (if accepted). Without prejudice to the above, Nexans may disclose information to third parties that are part of the same economic group as Nexans, for the purposes of executing this proposal, if necessary.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics